Proline t-mass A 150 Thermal mass flowmeter
Specifications
Features
Measuring Principle : Thermal
Product headline :
The flowmeter for cost‐effective measurement and easy monitoring of utility gases. Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.
Sensor features :
Optimal process monitoring–easy measurement even at low pressures and flow velocities.
Costeffective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending–multivariable measurement. Inline version: nominal diameter DN 15 to 50 (½ to 2"). Process pressure up to PN 40, Class 300.
Transmitter features :
Fast and efficient commissioning – guided operating menus. High plant availability–self-diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output.
Nominal diameter range : DN 15 to 50 (½ to 2")
Wetted materials :
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L)
Measuring tube: 1.4404 (316L); 1.4435 (316L)
Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L)
Measured variables : Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measured error :
3 % o.r. 4 % o.r. 5 % o.f.s. (depending on chosen option of ordering feature "Calibration flow" )
Measuring range :
0.5 to 910 kg/h (1.1 to 2002 lb/h)
0.5 to 1365 kg/h (1.1 to 3003 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
Max. process pressure : PN 40, Class 300
Medium temperature range : –40 to +100 °C (–40 to +212 °F)
Ambient temperature range : –40 to +60 °C (–40 to +140 °F)
Transmitter housing material : AlSi10Mg, coated
Degree of protection : IP66/67, type 4X enclosure
Display/Operation :
4‐line display with push Buttons
Configuration via local display and operating tools possible
Outputs :
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs : Status input
Digital communication : HART
Power supply : DC 18 to 30 V
Hazardous area approvals : ATEX, IECEx, cCSAus
Other approvals and certificates :
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
PED, CRN